Feedwater Equipment
Cleaver-Brooks Deaerators
Removes oxygen and other dissolved gases in the boiler feedwater including carbon dioxide. Reduces chemical and boiler blowdown costs while protecting the boiler and system from corrosion.
Tray style, spray style, packed column, boilermate and duo tank
1,500 – 280,000 Lbs/hr
Steam and hot water applications
BFS Industries Deaerators
Removes oxygen and other dissolved gases in the boiler feedwater including carbon dioxide. Reduces chemical and boiler blowdown costs while protecting the boiler and system from corrosion.
Tray style, spray style, packed column, boilermate and duo tank
1,500 – 280,000 Lbs/hr
Steam and hot water applications
Cleaver-Brooks Boiler Feed System
Maintains efficiency and prolongs the life of a boiler when a deaerator is not practical. We can customize any system to your application.
Atmospheric pressure
Up to 1,000 gallons
Steam and hot water applications
BFS Industries Boiler Feed System
Equipped with heavy gauge carbon steel tanks in standard capacities from 30 gallons to 2,000 gallons.We can customize any system to your application.
Atmospheric pressure
Up to 2,000 gallons
Steam and hot water applications
Cleaver-Brooks Surge Tank
The storage you need to handle volume swings in condensate returns.
300 – 3,600 gallons
Steam and hot water applications
Cleaver-Brooks Condensate Return System
Helps to improve energy efficiency, reduce chemical costs, reduce make-up water costs, reduce sewer system disposal costs and meet environmental regulations by returning condensate back to the system.
Simplex or Duplex / Single or 3-phase design
10, 15, 25, 35 gallon capacity
Steam and hot water applications
Boiler Controls
Cleaver-Brooks Boiler Controls
Boiler controls increase efficiency and reduce fuel costs with integrated boiler room controls, SCADA systems, building automation system communications and fuel monitoring. Cleaver-Brooks offers a full line of integrated boiler controls, communication systems, packaged water controls, water level controls and stand-alone controls for new or retrofit applications. Increase efficiency, reduce fuel costs and decrease emissions with control systems designed to get the most out of your boiler room.
- Integrated Boiler Controls - PLC-based from a Hydronic System Control for condensing, non-condensing and hybrid boiler applications to advanced boiler room controls that will aid in maximizing efficiency and save fuel.
- Communication Systems - Transfer data from boiler controls to external building automation, SCADA or remote monitoring systems.
- Customized Industrial Controls - Custom-designed control units to meet the needs of your specific boiler room.
- Packaged Water Controls - Monitor and manage all water-related touch points including pumps and level controls.
- Water Level Controls - Easy management of low water cutoff and pump control - essential for safety.
- Stand Alone Controls - Improve burner performance and maximize efficiency with user-friendly setup and operation.
Water Treatment
Cleaver-Brooks Water Softeners
Removes water hardness through ion exchange preventing scale buildup on heat transfer surfaces while maintaining peak boiler efficiency.
From 20,000 to 1,500,000 grains exchange capacity
Steam and hot water applications
Cleaver-Brooks Dealkalizers
Dealkalizers remove the majority of bicarbonate alkalinity in
From 10,000 to 980,000 grains capacity
Steam and hot water applications
from 10 to 300 gpm
From 9” to 72”
Cleaver-Brooks Filtration Systems
Remove impurities with a filtration system and mitigate equipment servicing, cleaning
From 50,000 to 100,000 grains capacity
Steam and hot water applications
from 2 to 800 gpm
From 9” to 72”
Cleaver-Brooks Chemical Feed System
Chemical feed systems treat feedwater and condition blowdown sludge when an extra measure of protection against corrosion is necessary.
For any boiler size
Steam and hot water applications
Cleaver-Brooks Blowdown Separator
Prevents scale and buildup of harmful solids.
Steam boilers
Up to 1,600 PSIG available
Cleaver-Brooks Sample Cooler
Cools water for water sampling without interrupting boiler operation.
Any boiler size
Steam applications
Burners
Cleaver-Brooks Commercial Burners
Forced draft and dual-fuel burners
0.4 to 16.8 MMBTU input range or 9 to 380 HP
For firetube, watertube, commercial watertube, firebox and cast iron boilers. Ideal for everything from process heating applications to building heat, sterilization, humidification and more.
Gas, #2 and or #6 oil, combination or alternative fuels
Range from <9 ppm, <30 ppm and uncontrolled NOx
Heat Recovery
Cleaver-Brooks Heat Recovery
Reduce costs and environmental impact by recovering waste heat or steam and using it for other system applications.
- Stack economizer - Reduce fuel usage and cost by recovering heat from flue gases that would otherwise be wasted.
- Condensing Economizer - Save on fuel costs and increase fuel-to-steam efficiency up to 90%.
- Flash Tank Heat Recovery - Save fuel and spend by recovering heat and steam to heat feedwater or use as-is.
- Blowdown Heat Recovery Systems - Recover 90% of heat normally lost by controlling surface blowdown flow.
- Heat Recovery Steam Generator - Package with turbines from 1 to 45 MW - customized for your application.
- Waste Heat Boilers - Reduce fuel and energy expenses in addition to greenhouse gas emissions. Up to 150,000 lb/hr of steam flow.
Boiler Exhaust
Cleaver-Brooks Boiler Exhaust
Installation-ready and engineered freestanding stacks with the latest engineering and technology in combustion gas venting for commercial industrial and institutional applications.
- Prefabricated Boiler Stacks - For vent flue gases from gas, liquid, oil or solid fuel fired appliances.
- Freestanding Stacks For Any Application - Available in carbon steel and stainless steel.
- Gas Vents - Installation-ready for condensing boilers.
- Chimney Liners - Have male/female slip-type jointing system for your masonry chimney
- Grease Duct - The industry’s best solution for the removal of smoke and grease-laden vapors.